Low pressure drop series

Flow meter VL02 · Flow controller VLC02

Pressure-drop-sensitive gas lines. Low pressure drop combined with good pressure resistance.

VL02 flow meter
Flow meter VL02
VLC02 flow controller
Flow controller VLC02
0.5 SCCM – 500 SLPMFlow meter range
0.5 SCCM – 50 SLPMFlow controller range
±max(0.6%RD, 0.1%FS)Accuracy (10 SCCM – 25 SLPM)
124Gas typesSee the list →

Specifications compared

The flow meter and flow controller share the same laminar differential pressure measurement platform; the controller adds a proportional valve and control functions.

ItemFlow meter VL02Flow controller VLC02
Range0.5 SCCM – 500 SLPM0.5 SCCM – 50 SLPM
Accuracy (10 SCCM – 25 SLPM)±max(0.6%RD, 0.1%FS)
Repeatability (10 SCCM – 25 SLPM)±max(0.1%RD, 0.02%FS)
Turndown ratio1:1000, 1:10000 optional
Response timeMeasurement < 10 msMeasurement < 10 ms; control as fast as < 100 ms
Warm-up< 1 s to within rated accuracy
Gas types124 (including humid air and predefined gas mixtures; no corrosive gases)See the list →
Working pressure0–0.5 MPaG (expandable to 0–1 MPaG)
Max. withstand pressure< 1.2 MPaG1.2 MPaG
Max. differential pressure0.4 MPaD1.2 MPaD
Operating temperature−10 to 60 °C (expandable to −20 to 70 °C)
Annual drift<0.1%FS (in clean, non-corrosive gas)
Power supply4.75 – 30 VDC; 2 W4.75 – 30 VDC; 0.5 SCCM – 20 SLPM: 5 W, 25 and 50 SLPM: 15 W
Power connectorUSB Type-C, DB9 male
Digital interfaceModbus RTU (RS485), USB (USB-to-serial)
Analog I/O0–20 mA / 4–20 mA / 0–5 VDC / 1–5 VDC / 0–10 VDC (software selectable)
Ingress protectionIP40
Wetted materials304 stainless steel, aluminum, gold, alumina ceramic, glass, epoxy, silicone, silicon300-series stainless steel, 400-series stainless steel, aluminum, gold, alumina ceramic, glass, epoxy, silicone, silicon
Seal materialFKM standard; EPDM, NBR and others optional

Accuracy and repeatability

Tiers follow the nominal full scale of the model, not the current reading. RD: reading; FS: nominal full scale; max: the larger of the two terms. These figures apply after flow zeroing, with temperature, pressure and humidity in equilibrium.

Flow meter VL02
Range0.5 SCCM – 5 SCCM10 SCCM – 25 SLPM50 – 500 SLPM
Accuracy±(0.8%RD + 0.2%FS)±max(0.6%RD, 0.1%FS)±(0.8%RD + 0.2%FS)
Repeatability±(0.2%RD + 0.02%FS)±max(0.1%RD, 0.02%FS)±(0.2%RD + 0.02%FS)
Flow controller VLC02
Range0.5 SCCM – 5 SCCM10 SCCM – 25 SLPM50 SLPM
Accuracy±(0.8%RD + 0.2%FS)±max(0.6%RD, 0.1%FS)±(0.8%RD + 0.2%FS)
Repeatability±(0.2%RD + 0.02%FS)±max(0.1%RD, 0.02%FS)±(0.2%RD + 0.02%FS)

Process connections

All ports are female threads. The venting pressure drop of the flow meter is given in PaD.

Flow meter VL02
Flow RangeStandard PortOptional PortsVenting Pressure Drop
0.5 – 5 SCCMG1/8M5, PT1/8, NPT1/8< 650 PaD
10 SCCM – 2 SLPMG1/8PT1/8, NPT1/8< 1000 PaD
5 – 10 SLPMG1/4PT1/4, NPT1/4< 1000 PaD
25 SLPMPT1/2G1/2, NPT1/2< 1200 PaD
50 – 100 SLPMPT3/4G3/4, NPT3/4< 1500 PaD
200 – 300 SLPMPT1G1, NPT1< 2000 PaD
500 SLPMPT2G2, NPT2< 2000 PaD
Flow controller VLC02
Flow RangeStandard PortOptional PortsInlet Pressure Range
0.5 – 100 SCCMG1/8PT1/8, NPT1/8Customized on request
300 – 500 SCCMG1/8PT1/8, NPT1/8Customized on request
1 – 2 SLPMG1/8PT1/8, NPT1/8Customized on request
5 SLPMG1/4PT1/4, NPT1/4Customized on request
10 SLPMG1/4PT1/4, NPT1/4Customized on request
25 SLPMPT1/2G1/2, NPT1/2Customized on request
50 SLPMPT3/4G3/4, NPT3/4Customized on request

Venting pressure drop: the pressure difference between inlet and outlet at nominal full-scale flow, with dry air at 20 °C and 0.1 MPaA, the outlet open to atmosphere and the inlet connected to the gas supply. Inlet pressure ranges are given for standard models at nominal full-scale flow with the outlet vented, and can be customized on request.

Documents

  • VL02 flow meter datasheetPDF
  • VLC02 flow controller datasheetPDF
  • V series user manualPDF

Other series

Tell us your gas, flow and pressure

Our engineers will recommend the full model number and send the matching datasheet.

+86-755-23097806

Tell us what you need

Leave your contact details and we will get back to you shortly.

Page:

Your contact details are used only to reply to this inquiry. By sending, you agree that we process your information under our Privacy Policy.